{"product_id":"cisco-sg250x-48-k9-switch-3i1wv","title":"Cisco SG250X-48-K9 Switch","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eManaged, Rack-mountable, 48 x 1G ports, 4 x 10G SFP+ Uplinks, No PoE (Data Only), Layer 3\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"584\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"378\"\u003eSG250X-48-K9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"378\"\u003e48 10\/100\/1000 ports\u003cbr data-mce-fragment=\"1\"\u003e4 10 Gigabit Ethernet (2 x 10GBASE-T + 2 x SFP+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSG250 - SF250 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSmall Business Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eNumber of Ports (Gigabit Ethernet)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e48 Gigabit Ethernet + 4 10 Gigabit Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRJ-45 ports (Gigabit Ethernet)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eDownlinks total 10\/100\/1000 ports\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePower dedicated to PoE\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eNumber of ports that support PoE\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePower\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e100 to 240V 50 to 60 Hz, internal, universal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eFans\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eUnit dimensions in. (W x D x H)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e17.3 x 1.73 x 10.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRack-mountable\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 1045pt;\" width=\"1393\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 24087; width: 518pt;\" width=\"690\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 24529; width: 527pt;\" width=\"703\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003eSG250X-48-K9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003eCapacity in millions of packets (mpps)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003e130.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003eSwitching capacity (Gbps)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003e176.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003e256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003eCPU\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003e800 MHz ARM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003eCPU Memory\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003e512MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003ePacket Buffer\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003e24 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003eMAC addresses\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003e8K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003eHead-of-line (HOL) blocking\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003eHOL blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 29.0pt;\" height=\"39\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 29.0pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"39\"\u003eQuality of Service (QoS)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003e8 hardware queues, Strict priority and Weighted Round-Robin (WRR) queue assignment based on DSCP and class of service (802.1p\/CoS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 29.0pt;\" height=\"39\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 29.0pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"39\"\u003eLoopback detection\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003eProvides protection against loops by transmitting loop protocol packets out of ports on which loop protection has been enabled. It operates independently of STP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 145.0pt;\" height=\"193\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 145.0pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"193\"\u003eStandards\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003eIEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3ad Link Aggregation Control Protocol, IEEE 802.3z Gigabit Ethernet, IEEE 802.3x Flow Control, IEEE 802.3 ad LACP, IEEE 802.1D (STP), IEEE 802.1Q\/p VLAN, IEEE 802.1w RSTP, IEEE 802.1s Multiple STP, IEEE 802.1X Port Access Authentication, IEEE 802.3af, IEEE 802.3at, RFC 768, RFC 783, RFC 791, RFC 792, RFC 793, RFC 813, RFC 879, RFC 896, RFC 826, RFC 854, RFC 855, RFC 856, RFC 858, RFC 894, RFC 919, RFC 920, RFC 922, RFC 950, RFC 951, RFC 1042, RFC 1071, RFC 1123, RFC 1141, RFC 1155, RFC 1157, RFC 1213, RFC 1215, RFC 1286, RFC 1350, RFC 1442, RFC 1451, RFC 1493, RFC 1533, RFC 1541, RFC 1542, RFC 1573, RFC 1624, RFC 1643, RFC 1700, RFC 1757, RFC 1867, RFC 1907, RFC 2011, RFC 2012, RFC 2013, RFC 2030, RFC 2131, RFC 2132, RFC 2233, RFC 2576, RFC 2616, RFC 2618, RFC 2665, RFC 2666, RFC 2674, RFC 2737, RFC 2819, RFC 2863, RFC 3164, RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 3416, RFC 4330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003e32° to 122°F (0° to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003e10% to 90%, relative, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 18.5pt;\" height=\"25\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 18.5pt; width: 518pt;\" width=\"690\" class=\"xl68\" height=\"25\"\u003eCompliance\/certifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"width: 527pt;\" width=\"703\" class=\"xl68\"\u003eUL (UL 60950), CSA (CSA 22.2), CE mark, FCC Part 15 (CFR 47) Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e[\/specifications]\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e[accesories]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"465\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" width=\"465\"\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eLEDs\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eSystem, Link\/Act, PoE, Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eCabling type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eUnshielded Twisted Pair (UTP) Category 5 or better for 10BASE-T\/100BASE-TX; UTP Category 5e or better for 1000BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eMounting options\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eDesktop placement, rackmount (excluding SG250-08 and SG250-08HP) and wall-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eAccessories\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eThere is no additional accessory other than the mounting kit and power cord included in the product package.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" width=\"465\"\u003eSupported SFP modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eSKU\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eMedia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eMGBBX1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eSingle-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eMGBSX1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eMultimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eMGBLH1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eSingle-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eMGBLX1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eSingle-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eMGBT1\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eUTP cat 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eGLC-LH-SMD=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eSingle-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eGLC-BX-U=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eSingle-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eSFP-H10GB-CU1M\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eCopper coax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eSFP-H10GB-CU3M\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eCopper coax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eSFP-H10GB-CU5M\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eCopper coax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eSFP-10G-SR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eMultimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eSFP-10G-LR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eSingle-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eSFP-10G-SR-S\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eMultimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eSFP-10G-LR-S\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eSingle-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003ePackage contents\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eCisco 250 Series Smart Switch\u003cbr data-mce-fragment=\"1\"\u003ePower cord (power adapter for 8-port and 10-port SKUs)\u003cbr data-mce-fragment=\"1\"\u003eQuick start guide\u003cbr data-mce-fragment=\"1\"\u003eMounting kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"219\"\u003eMinimum requirements\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"246\"\u003eWeb browser: Mozilla Firefox version 36 or later; Microsoft Internet Explorer version 9 or later, Chrome version 40 or later, Safari version 5 or later \u003cbr data-mce-fragment=\"1\"\u003eCategory 5 Ethernet network cable\u003cbr data-mce-fragment=\"1\"\u003eTCP\/IP, network adapter, and network operating system (such as Microsoft Windows, Linux, or Mac OS X) installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eCisco SG250X-48-K9 Switch\u003c\/h2\u003e\n\u003cp\u003eThe Cisco SG250X-48-K9 is a high-performance managed switch designed for growing businesses that require advanced networking features and scalable 10 Gigabit Ethernet connectivity. With 48 Gigabit Ethernet ports and 4 10 Gigabit Ethernet uplink ports, this switch provides powerful networking capabilities for bandwidth-intensive applications. The SG250X-48-K9 ensures seamless network performance with Layer 2\/3 support, advanced security features, and energy-efficient operation.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e48 x Gigabit Ethernet Ports:\u003c\/strong\u003e Provides fast, reliable connections for business-critical applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 x 10 Gigabit Ethernet Uplink Ports (2 x 10GBase-T + 2 x SFP+):\u003c\/strong\u003e Offers high-speed uplink options for flexible network expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLayer 2\/3 Features:\u003c\/strong\u003e Includes VLANs, QoS, and static routing for optimized traffic segmentation and management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy-Efficient Design:\u003c\/strong\u003e Compliant with IEEE 802.3az standards, reducing energy consumption during low-traffic periods.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Security:\u003c\/strong\u003e Includes 802.1X authentication, IP Source Guard, and ACLs to protect your network from unauthorized access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Overview:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended for:\u003c\/strong\u003e Medium-sized businesses and enterprise networks requiring high-speed connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 48 x 10\/100\/1000 ports, 4 x 10GBase-T\/SFP+ uplink ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e 176 Gbps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForwarding Rate:\u003c\/strong\u003e 130.94 Mpps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLayer 2\/3 Features:\u003c\/strong\u003e VLANs, static routing, QoS, and IGMP snooping for efficient traffic management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManagement:\u003c\/strong\u003e Cisco Business Dashboard, Web-based GUI, CLI, and SNMP for easy network control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e ACLs, 802.1X authentication, and IP Source Guard for enhanced network security.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Efficiency:\u003c\/strong\u003e Compliant with IEEE 802.3az standards for energy-efficient operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou can check the related tab for the \u003cstrong\u003eSG250X-48-K9\u003c\/strong\u003e datasheet.\u003c\/p\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":48013277298905,"sku":"SG250X-48-K9-NEW","price":1064.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/SG250X-48-K9_1_dd29d215-5e48-477c-9219-ab60635479ee.webp?v=1771853208","url":"https:\/\/www.aloinfobrasil.com\/bn\/products\/cisco-sg250x-48-k9-switch-3i1wv","provider":"aloinfousa.com","version":"1.0","type":"link"}