{"product_id":"endress-hauser-7f2c-proline-prowirl-f200-vortex-flowmeter","title":"Endress+Hauser 7F2C Proline Prowirl F200 Vortex Flowmeter","description":"\u003ch1\u003eOverview\u003c\/h1\u003e\u003cp\u003eEndress+Hauser Proline Prowirl F200 Vortex Flowmeter is a versatile flowmeter with detection of wet steam conditions and best-in-class accuracy.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e* Max. measurement error \u003cbr\u003eVolume flow (liquid): ±0.75 % \u003cbr\u003eVolume flow (optional): ±0.65 % \u003cbr\u003eVolume flow (steam, gas): ±1.00 % \u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated) \u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure \u003cbr\u003ecompensation) \u003cbr\u003eMass flow (liquid): ±0.85% \u003cbr\u003e* Measuring range \u003cbr\u003eLiquid: 0.076 to 2100 m³\/h (0.045 to 1300 ft³\/min) \u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) \u003cbr\u003eSteam, gas: 0.39 to 28000 m³\/h (0.23 to 17000 ft³\/min) \u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) \u003cbr\u003e* Medium temperature range \u003cbr\u003eStandard: –40 to +260 °C (–40 to +500 °F) \u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F) \u003cbr\u003e* Max. process pressure \u003cbr\u003ePN 100, Class 600, 20K \u003cbr\u003e* Wetted materials \u003cbr\u003eMeasuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602 \u003cbr\u003eDSC sensor: 1.4404 (316\/316L); UNS N06022 similar to Alloy C22, 2.4602 \u003cbr\u003eProcess connection: 1.4404\/F316\/F316L); 2.4602\u003c\/p\u003e\u003ch1\u003eField of application\u003c\/h1\u003e\u003cp\u003eProwirl F is the multivariable flowmeter with inline wet steam measurement. Its calibration option PremiumCal guarantees excellent measuring accuracy and highest plant availability at low flow rates of gas, steam and liquids. With genuine loop-powered technology, Prowirl F 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.\u003cbr\u003e* Preferred measuring principle for wet\/saturated\/superheated steam, gases \u0026amp; liquids (also cryogenic)\u003cbr\u003e* Suitable for a wide range of applications; optimized for steam applications\u003cbr\u003eDevice properties\u003cbr\u003e* Wet steam capabilities for DN 25 to 300 (1 to 12\")\u003cbr\u003e* Flexible positioning of pressure cell\u003cbr\u003e* Industrial siphon design for pressure measurement\u003cbr\u003e* Display module with data transfer function\u003cbr\u003e* Robust dual-compartment housing\u003cbr\u003e* Plant safety: worldwide approvals (SIL, Haz. area)\u003c\/p\u003e\u003ch1\u003eBenefits\u003c\/h1\u003e\u003cp\u003e * Easy energy management – integrated temperature and pressure measurement for steam and gases\u003cbr\u003e* Reliable, secure measurement technology – compliance with international Vortex standard ISO 12764\u003cbr\u003e* Same accuracy down to Re 10 000 – most linear Vortex meter body\u003cbr\u003e* Long-term stability – robust drift-free capacitive sensor\u003cbr\u003e* Convenient device wiring – separate connection compartment, various Ethernet options\u003cbr\u003e* Safe operation – no need to open the device\u003cbr\u003e* Integrated verification – Heartbeat Technology\u003c\/p\u003e\u003ch1\u003eSpecification\u003c\/h1\u003e\u003cfigure class=\"table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eitem\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003evalue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCustomized support\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePlace of Origin\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eEndress+Hauser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eModel Number\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProwirl F200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eType\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVortex Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Headline\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVersatile flowmeter with detection of wet steam conditions and best-in-class accuracy. \u003cbr\u003eEasy energy management – integrated temperature and pressure measurement for steam and gases. \u003cbr\u003eSuitable for a wide range of applications; optimized for steam applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSpace-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term \u003cbr\u003estability – robust drift-free capacitive sensor. \u003cbr\u003eWet steam capabilities for DN 25 to 300 (1 to 12\"). Flexible positioning of pressure cell. Industrial siphon design for pressure \u003cbr\u003emeasurement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch \u003cbr\u003econtrol, background lighting. Integrated verification – Heartbeat Technology. \u003cbr\u003eDisplay module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNominal Diameter Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDN 15 to 300 (½ to 12\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWetted Materials\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602 \u003cbr\u003eDSC sensor: 1.4404 (316\/316L); UNS N06022 similar to Alloy C22, 2.4602 \u003cbr\u003eProcess connection: 1.4404\/F316\/F316L); 2.4602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasured Variables\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Measurement Error\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow (liquid): ±0.75 % \u003cbr\u003eVolume flow (optional): ±0.65 % \u003cbr\u003eVolume flow (steam, gas): ±1.00 % \u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated) \u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure \u003cbr\u003ecompensation) \u003cbr\u003eMass flow (liquid): ±0.85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLiquid: 0.076 to 2100 m³\/h (0.045 to 1300 ft³\/min) \u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) \u003cbr\u003eSteam, gas: 0.39 to 28000 m³\/h (0.23 to 17000 ft³\/min) \u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Process Ppressure\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePN 100, Class 600, 20K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMedium Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eStandard: –40 to +260 °C (–40 to +500 °F) \u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version (standard): –40 to +80 °C (–40 to +176 °F) \u003cbr\u003eCompact version (option): –50 to +80 °C (–58 to +176 °F) \u003cbr\u003eRemote version (standard): –40 to +85 °C (–40 to +185 °F) \u003cbr\u003eRemote version (option): –50 to +85 °C (–58 to +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAlSi10Mg, coated; 1.4404 (316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDegree Of Protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version: IP66\/67, type 4X enclosure \u003cbr\u003eSensor remote version: IP66\/67, type 4X enclosure \u003cbr\u003eTransmitter remote version: IP66\/67, type 4X enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐line backlit display with touch control (operation from outside) \u003cbr\u003eConfiguration via local display and operating tools possible \u003cbr\u003eRemote display available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA HART (passive) \u003cbr\u003e4‐20 mA (passive) \u003cbr\u003ePulse\/frequency\/switch output (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCurrent Input 4‐20 mA (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHART, PROFIBUS PA, FOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDC 12 to 35 V (4‐20 mA HART with\/without pulse\/frequency\/switch output) \u003cbr\u003eDC 12 to 30 V (4‐20 mA HART, 4‐20 mA) \u003cbr\u003eDC 12 to 35 V (4‐20 mA HART, pulse\/frequency\/switch output, 4‐20 mA input) \u003cbr\u003eDC 9 to 32 V (PROFIBUS PA, pulse\/frequency\/switch output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHazardous Area Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eATEX, IECEx, cCSAus, JPN, EAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCE, C-TICK, EAC, UK Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMetrological Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025) \u003cbr\u003eHeartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a \u003cbr\u003e(TÜV SÜD attestation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMarine aApprovals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eABS, LR, BV, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePressure Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePED, CRN, AD 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3.1 material \u003cbr\u003eNACE MR0175\/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020368228569,"sku":null,"price":3125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_7F2C_Proline_Prowirl_F_200_Vortex_Flowmeter.png?v=1771970605","url":"https:\/\/www.aloinfobrasil.com\/bn\/products\/endress-hauser-7f2c-proline-prowirl-f200-vortex-flowmeter","provider":"aloinfousa.com","version":"1.0","type":"link"}