{"product_id":"cisco-pwr-ie65w-pc-dc-power-supply-fhdo5","title":"Cisco PWR-IE65W-PC-DC Power Supply","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003ePower converter (DIN Rail Mountable)\u003c\/li\u003e\n\u003cli\u003e18\u003c\/li\u003e\n\u003cli\u003e60 V\u003c\/li\u003e\n\u003cli\u003e65 Watt\u003c\/li\u003e\n\u003cli\u003efor Industrial Ethernet 1000\/2000\/3000\/4000 Series\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable width=\"502\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eProperties\u003c\/td\u003e\n\u003ctd width=\"302\"\u003eCisco PWR-IE65W-PC-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eDescription\u003c\/td\u003e\n\u003ctd width=\"302\"\u003eDC-DC, 54VDC power module to support 65 watts for PoE\/PoE+ modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eIndustrial Ethernet 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eConfigurations\u003c\/td\u003e\n\u003ctd width=\"302\"\u003eDC-DC Power Module for PoE solution, Input DC 18-60 V\/4.3A, Output DC 54V\/1.2A, DIN-Rail Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd width=\"302\"\u003e2.6W x 5.9H x 4.6D (66mm W x 150mm H x 117mm D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 (1.18 Kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eInput voltage and currents supported\u003c\/td\u003e\n\u003ctd width=\"302\"\u003e18-60VDC\/4.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"200\"\u003eOutput\u003c\/td\u003e\n\u003ctd width=\"302\"\u003e54VDC\/1.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties][specifications]\u003c\/p\u003e\n\u003ctable width=\"753\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd width=\"369\"\u003ePWR-IE65W-PC-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eMean Time Between Failures (MTBF)\u003c\/td\u003e\n\u003ctd width=\"369\"\u003e2,468,430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd width=\"369\"\u003e-40C to +75C\u003cbr\u003e-40C to +70C (Vented Enclosure 40 LFM Air Flow)\u003cbr\u003e-40C to +60C (Sealed Enclosure 0 LFM Air Flow)\u003cbr\u003e-24C to +75C (Fan or Blower equipped Enclosure 200 LFM Air Flow)\u003cbr\u003e-40C to +85C (IEC 60068-2-2 Environmental Type Testing 16 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eUp to 13,000 ft (3963m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eUp to 15,000 ft (4573m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eStandard safety certifications\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eUL 60950-1\u003cbr\u003eCSA C22.2 No. 60950-1\u003cbr\u003eTUV\/GS to EN 60950-1\u003cbr\u003eCB to IEC 60950-1 with all country deviations\u003cbr\u003eNOM\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eElectromagnetic emissions\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eFCC Part 15 Class A\u003cbr\u003eEN 55022\u003cbr\u003eCISPR 22\u003cbr\u003eCISPR11\u003cbr\u003eVCCI Class A\u003cbr\u003eAS\/NZS 3548 Class A\u003cbr\u003eCNS 13438 Class A\u003cbr\u003eKN 22 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic immunity\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eEN 55024\u003cbr\u003eAS\/NZS CISPR 24\u003cbr\u003eKN 24\u003cbr\u003eIEC\/EN 61000-4-2 (Electro Static Discharge)\u003cbr\u003eIEC\/EN 61000-4-3 (Radiated Immunity)\u003cbr\u003eIEC\/EN 61000-4-4 (Fast Transients)\u003cbr\u003eIEC\/EN 61000-4-5 (Surge)\u003cbr\u003eIEC\/EN 61000-4-6 (Conducted Immunity)\u003cbr\u003eIEC\/EN 61000-4-8 (Power Frequency Magnetic Field Immunity)\u003cbr\u003eIEC\/EN 61000-4-9 (Pulse Magnetic Field Immunity)\u003cbr\u003eIEC\/EN 61000-4-10 (Oscillatory Magnetic Field Immunity)\u003cbr\u003eIEC\/EN 61000-4-11 (AC power Voltage Immunity)\u003cbr\u003eIEC\/EN 61000-4-16 (Low Frequency Conducted CM Disturbances)\u003cbr\u003eIEC\/EN 61000-4-17 (Ripple on DC Input Power)\u003cbr\u003eIEC\/EN 61000-4-18 (Damped Oscillatory Wave)\u003cbr\u003eIEC\/EN 61000-4-29 (Voltage Dips Immunity, DC power)\u003cbr\u003eIEEE C37.90 (Surge)\u003cbr\u003eIEEE C37.90.1 (Fast Transients)\u003cbr\u003eIEEE C37.90.2 (Radiated Immunity)\u003cbr\u003eIEEE C37.90.3 (Electro Static Discharge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical stability\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eIEC 60628-2-27 Shock 20g (operational), 30g (nonoperational)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustry specifications\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eEN 61131-2 Programmable Controllers (EMC\/EMI, environmental, mechanical)\u003cbr\u003eIEEE 1613 Power Station and Substation Networking Devices\u003cbr\u003eIEC 61850-3 Power Station and Substation Communication Networks and Systems\u003cbr\u003eEN 61326-1 Electrical Equipment for Measurement, Control and Laboratory Use - EMC\u003cbr\u003eEN 61000-6-1 Immunity for Light Industrial Environments\u003cbr\u003eEN 61000-6-2 Immunity for Industrial Environments\u003cbr\u003eEN 61000-6-4 Emissions for Industrial Environments\u003cbr\u003eTS 61000-6-5 EMC Immunity for Power Station and Substation\u003cbr\u003eEN 50155 Railway, Electronic Equipment on Rolling Stock (EMI\/EMC, environmental, mechanical)\u003cbr\u003eEN 50121-3-2 Railway, Electromagnetic Compatibility on Rolling Stock\u003cbr\u003eEN 50121-4 Railway, Emission and Immunity of Signaling and Telecommunications Apparatus\u003cbr\u003eEN 60945 Maritime Navigation and Radio-communication Equipment and Systems\u003cbr\u003eIEC 60533 Shipboard Electrical and Electronic Installation EMC\u003cbr\u003eMarine Type Approval (BV, DNV, Korean Register, Lloyd Register)\u003cbr\u003eNEMA TS-2 (EMC, environmental, mechanical)\u003cbr\u003eABB Industrial IT certification\u003cbr\u003eODVA Industrial EtherNet\/IP support\u003cbr\u003ePROFINETv2 support\u003cbr\u003eDirective 2011\/65\/EU RoHS\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous locations\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eUL\/CSA 60079-0, -15 (Class 1, Div 2 A-D) (requires cabinet enclosure)\u003cbr\u003eEN 60079-0, -15 ATEX Certification (Class 1, Zone 2 A-D) (requires cabinet enclosure)\u003cbr\u003eIEC 60079-0, -15 (Test report only) (requires cabinet enclosure)\u003cbr\u003eUL 508\u003cbr\u003eCSA C22.2 No. 142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"384\"\u003eHumidity\u003c\/td\u003e\n\u003ctd width=\"369\"\u003eRelative humidity: 5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003ch2\u003eCisco PWR-IE65W-PC-DC Power Supply\u003c\/h2\u003e\n\u003cp\u003eCisco's industrial din-rail power supply portfolio provides versatile options for powering industrial networking equipment. They support high-capacity Power over Ethernet (PoE) and are available with conformal coating options. The PWR-IE65W-PC-DC is low DC to DC power supply specific to Cisco Industrial Ethernet (IE)3000 series switches which has 65 watts of power and is DIN rail-mountable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e65W\u003c\/li\u003e\n\u003cli\u003eHigh-capacity PoE\u003c\/li\u003e\n\u003cli\u003eFor Cisco IE3000 series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor detailed specifications, refer to the Cisco PWR-IE65W-PC-DC datasheet in the tabs.\u003c\/p\u003e\n\u003cdiv id=\"gtx-anchor\" style=\"position: absolute; visibility: hidden; left: 11.9907px; top: 2835.69px; width: 88.2222px; height: 18.5185px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"jfk-bubble gtx-bubble\" role=\"alertdialog\" aria-describedby=\"bubble-3\" style=\"visibility: visible; left: 41px; top: 2715px; opacity: 1;\"\u003e\n\u003cdiv class=\"jfk-bubble-content-id\" id=\"bubble-3\"\u003e\n\u003cdiv id=\"gtx-host\" style=\"min-width: 200px; max-width: 400px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"jfk-bubble-closebtn-id jfk-bubble-closebtn\" aria-label=\"Close\" role=\"button\" tabindex=\"0\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"jfk-bubble-arrow-id jfk-bubble-arrow jfk-bubble-arrowdown\" style=\"left: 44px;\"\u003e\n\u003cdiv class=\"jfk-bubble-arrowimplbefore\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"jfk-bubble-arrowimplafter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":48013312393433,"sku":"PWR-IE65W-PC-DC-NEW","price":481.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/pwr-ie65w-pc-dc_2_e1539758-b5b1-4341-9869-7a61b7dacde7.webp?v=1771853890","url":"https:\/\/www.aloinfobrasil.com\/en\/products\/cisco-pwr-ie65w-pc-dc-power-supply-fhdo5","provider":"aloinfousa.com","version":"1.0","type":"link"}