{"product_id":"dell-xr8620t-rugged-heat-manager-subsystem-hm","title":"Dell XR8620t Rugged Heat Manager subsystem (HM)","description":"\u003cdiv class=\"product-default-container\"\u003e\n\u003cdiv class=\"hfour\"\u003eRugged Heat Manager subsystem(HM)\u003c\/div\u003e\n\u003cb\u003eWhat is a Heat Manager subsystem (HM)?\u003c\/b\u003e\n\u003chr\u003e\n\u003cp\u003e\u003ci\u003eHeater Manager subsystem (HM) will pre-heat the system to above 5C before the system can power on.\u003c\/i\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cdiv class=\"same_height jc-evenly\"\u003e\n\u003cdiv class=\"eight medium-down--one-whole-NG\"\u003e\n\u003cp\u003eWith a system like the XR8000 that supports Radio Access Network (RAN), these Telco systems are deployed in remote locations where the systems need to operate in extended (-20C to 39 65C) or extreme (-20C to 55C) temperature ranges. As many of the hardware components (such as iDRAC, 40 CPU, DIMM, SSD, etc.) used in the system cannot operate below 0C, the system needs to be pre-heated to above 5C before the system can power on. The Heater Manager subsystem (HM) will pre-heat the system, and make sure all the heater zones (9 zones total) are above 5C. The HM will heat the system as needed such that the temperature of all zones will be above 5C.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"eight medium-down--one-whole-NG\"\u003e\n  \u003cb\u003eRestrictions\u003c\/b\u003e\n\u003cul class=\"margin-empty\"\u003e\n\u003cli\u003eHeater Manager subsystem (HM) is only supported in 2U XR8620t.\u003c\/li\u003e\n\u003cli\u003eHeater Manager subsystem (HM) heating from -20C to system start booting: 4 minutes\u003c\/li\u003e\n\u003cli\u003eThe max power draw per 2U HM sled is about 750W during the preheat process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003chr\u003e\n  \u003cdiv class=\"product-default-container\"\u003e\n\u003cb\u003e9 Heating Zones\u003c\/b\u003e\n\u003cdiv class=\"table-mobile\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem\u003c\/th\u003e\n\u003cth\u003eZone\u003c\/th\u003e\n\u003cth\u003eHeating Item\u003c\/th\u003e\n\u003cth\u003eHeater pad location\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eLower U\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eCPU\u003c\/td\u003e\n\u003ctd\u003eTop of CPU heatsink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eDIMM\u003c\/td\u003e\n\u003ctd\u003eBack of PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eDIMM\u003c\/td\u003e\n\u003ctd\u003eBack of PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eLower U PCIe Riser Slot3\u003c\/td\u003e\n\u003ctd\u003ePCIe back of PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003ePCH, BMC, CPLD, and LOM\u003c\/td\u003e\n\u003ctd\u003eBack of PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eNot Used\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eUpper U\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eROR-N1 or M.2 NVMe A side\u003c\/td\u003e\n\u003ctd\u003eUnder AL plate \u0026amp; beneath M.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eROR-N1 or M.2 NVMe B side\u003c\/td\u003e\n\u003ctd\u003eUnder AL plate \u0026amp; beneath M.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eROR-N1 RAID chip\u003c\/td\u003e\n\u003ctd\u003eTop of Raid Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eUpper U PCIE Riser Slot2\u003c\/td\u003e\n\u003ctd\u003eOn the back of PCIe Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eUpper U PCIE Riser Slot1\u003c\/td\u003e\n\u003ctd\u003eOn back of Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003chr\u003e\n\u003cdiv class=\"same_height jc-evenly\"\u003e\n\u003cdiv class=\"one-third medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"view-server-no-description\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-zones-description_400x.jpg\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-zones-description_400x.jpg\" sizes=\"(min-width: 900px) 314px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"314\" height=\"175\" style=\"width: 100%; height: auto; display: block;\" title=\"Image of the HM Zones on the XR8620t Node Server By Dell.\" alt=\"Image of the HM Zones on the XR8620t Node Server By Dell.\"\u003e HM Zones\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-third medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"view-server-no-description\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-CPU-description_400x.jpg\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-CPU-description_400x.jpg 400w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-CPU-description_600x.jpg 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-CPU-description_900x.jpg 900w,\n    \" sizes=\"(min-width: 900px) 314px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"314\" height=\"175\" style=\"width: 100%; height: auto; display: block;\" title=\"Image of Zone 1 HM CPU on the XR8620t Node Server By Dell.\" alt=\"Image of Zone 1 HM CPU on the XR8620t Node Server By Dell.\"\u003e Zone 1 HM CPU\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-third medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"view-server-no-description\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-DIMM-description_400x.jpg\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-DIMM-description_400x.jpg 400w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-DIMM-description_600x.jpg 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-DIMM-description_900x.jpg 900w,\n    \" sizes=\"(min-width: 900px) 314px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"314\" height=\"175\" style=\"width: 100%; height: auto; display: block;\" title=\"Image of Zone 2 HM DIMM on the XR8620t Node Server By Dell.\" alt=\"Image of Zone 2 HM DIMM on the XR8620t Node Server By Dell.\"\u003e Zone 2 HM DIMM\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"same_height jc-evenly\"\u003e\n\u003cdiv class=\"one-fourth medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"view-server-no-description\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-r2-description_300x.jpg\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-r2-description_300x.jpg 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-r2-description_600x.jpg 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-r2-description_900x.jpg 900w,\n    \" sizes=\"(min-width: 900px) 230px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"230\" height=\"128\" style=\"width: 100%; height: auto; display: block;\" title=\"Image of Zone 4 Riser 2 Slot 3 on the XR8620t Node Server By Dell.\" alt=\"Image of Zone 4 Riser 2 Slot 3 on the XR8620t Node Server By Dell.\"\u003e Zone 4 Riser 2 Slot 3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-fourth medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"view-server-no-description\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-m2-riser-description_300x.jpg\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-m2-riser-description_300x.jpg 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-m2-riser-description_600x.jpg 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-m2-riser-description_900x.jpg 900w,\n    \" sizes=\"(min-width: 900px) 230px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"230\" height=\"128\" style=\"width: 100%; height: auto; display: block;\" title=\"Image of Zone 7 M.2 Riser on the XR8620t Node Server By Dell.\" alt=\"Image of Zone 7 M.2 Riser on the XR8620t Node Server By Dell.\"\u003e Zone 7 M.2 Riser\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-fourth medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"view-server-no-description\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-RoR-description_300x.jpg\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-RoR-description_300x.jpg 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-RoR-description_600x.jpg 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-RoR-description_900x.jpg 900w,\n    \" sizes=\"(min-width: 900px) 230px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"230\" height=\"128\" style=\"width: 100%; height: auto; display: block;\" title=\"Image of Zone 8 RoR-N1 on the XR8620t Node Server By Dell.\" alt=\"Image of Zone 8 RoR-N1 on the XR8620t Node Server By Dell.\"\u003e Zone 7 \u0026amp; 8 RoR-N1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"one-fourth medium-down--one-whole-NG product-section-extras specs\"\u003e\n\u003cdiv class=\"view-server-no-description\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-r1-description_300x.jpg\" srcset=\"\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-r1-description_300x.jpg 300w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-r1-description_600x.jpg 600w,\n        https:\/\/cdn.shopify.com\/s\/files\/1\/0065\/1906\/2613\/files\/delll-poweredge-xr5620t-HM-r1-description_900x.jpg 900w,\n    \" sizes=\"(min-width: 900px) 230px, (min-width: 408px) 100vw\" loading=\"lazy\" width=\"230\" height=\"128\" style=\"width: 100%; height: auto; display: block;\" title=\"Image of Zone 9 n 10 Riser 1 Slot 1 n 2 on the XR8620t Node Server By Dell.\" alt=\"Image of Zone 9 n 10 Riser 1 Slot 1 n 2 on the XR8620t Node Server By Dell.\"\u003e Zone 9 \u0026amp; 10 Riser 1 Slot 1 \u0026amp; 2\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Dell","offers":[{"title":"Default Title","offer_id":48888184963289,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/delll-poweredge-xr5620t-HM-zones.jpg?v=1783208407","url":"https:\/\/www.aloinfobrasil.com\/es\/products\/dell-xr8620t-rugged-heat-manager-subsystem-hm","provider":"aloinfousa.com","version":"1.0","type":"link"}