{"product_id":"endresshauser-vibronic-point-level-detection-liquiphant-ftl51c","title":"Endress+Hauser Vibronic Point Level Detection Liquiphant FTL51C","description":"\u003cstyle\u003e#detail_decorate_root .magic-0{width:750px}#detail_decorate_root .magic-1{overflow:hidden;width:750px;height:587px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-2{margin-top:0;margin-left:0;width:750px;height:587px}#detail_decorate_root .magic-3{overflow:hidden;width:750px;height:73px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-4{margin-top:0;margin-left:0;width:750px;height:73px}#detail_decorate_root .magic-5{width:446px}#detail_decorate_root .magic-6{overflow:hidden;width:446px;height:356.8px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-7{margin-top:-2.3786666666666667px;margin-left:51.141333333333336px;width:361px;height:361px}#detail_decorate_root .magic-8{width:300px;display:flex;flex-direction:column;margin-right:0;margin-left:4px}#detail_decorate_root .magic-9{font-size:20px}#detail_decorate_root .magic-10{vertical-align:top}#detail_decorate_root .magic-11{vertical-align:top;display:inline-block;padding-right:4px;width:50%;box-sizing:border-box;margin-bottom:-4px;padding-left:4px;margin-top:-4px}#detail_decorate_root .magic-12{padding:0;margin:0}#detail_decorate_root .magic-13{padding:0;margin:0;color:#333;font-size:14px;line-height:20px;font-weight:bold;white-space:pre-wrap}#detail_decorate_root .magic-14{vertical-align:top;padding-bottom:4px;box-sizing:border-box;padding-top:4px}#detail_decorate_root .magic-15{padding:0;margin:0;white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-16{white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-17{overflow:hidden;width:750px;height:75px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-18{margin-top:0;margin-left:0;width:750px;height:75px}#detail_decorate_root .magic-19{width:750px;border-collapse:collapse}#detail_decorate_root .magic-20{min-height:28px;padding:5px 10px;width:259px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-21{min-height:28px;padding:5px 10px;width:442px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-22{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-23{overflow:hidden;width:750px;height:1078px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-24{margin-top:0;margin-left:0;width:750px;height:1078px}#detail_decorate_root .magic-25{overflow:hidden;width:750px;height:814px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-26{margin-top:0;margin-left:0;width:750px;height:814px}#detail_decorate_root .magic-27{overflow:hidden;width:750px;height:758px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-28{margin-top:0;margin-left:0;width:750px;height:758px}#detail_decorate_root .magic-29{overflow:hidden;width:750px;height:583px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-30{margin-top:0;margin-left:0;width:750px;height:583px}#detail_decorate_root .magic-31{overflow:hidden;width:750px;height:893px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-32{margin-top:0;margin-left:0;width:750px;height:893px}#detail_decorate_root .magic-33{overflow:hidden;width:750px;height:675px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-34{margin-top:0;margin-left:0;width:750px;height:675px}#detail_decorate_root .magic-35{overflow:hidden;width:750px;height:76px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-36{margin-top:0;margin-left:0;width:750px;height:76px}#detail_decorate_root .magic-37{vertical-align:top;display:block;padding-right:4px;box-sizing:border-box;padding-left:4px}\u003c\/style\u003e\n\u003cdiv data-magic-global=\"%7B%22bizId%22%3A2217607044645%2C%22pageId%22%3A200110829629%2C%22siteId%22%3A10100897032%7D\" id=\"detail_decorate_root\"\u003e\n\u003cdiv module-id=\"201247375198\" module-title=\"detailSingleImage\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201247375200\" module-title=\"detailHorizontalImageText\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003ePoint level switch for liquids with highly corrosion-resistant coating.\u003c\/div\u003e\n\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e* Process temperature \u003cbr\u003e-50 °C...+150 °C \u003cbr\u003e(-58 °F...+302 °F) \u003cbr\u003eup to 230 °C \/ 450°F on request \u003cbr\u003e* Process pressure \/ max. overpressure limit \u003cbr\u003eVacuum...40 bar \u003cbr\u003e(Vacuum...580 psi) \u003cbr\u003e* Min. density of medium \u003cbr\u003e0.5g\/cm³ (0.4g\/cm³ optional)\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201247375201\" module-title=\"detailDoubleTitleParagraph\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eField of application\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eLiquiphant FTL51C is a point level switch with extension tube and highly corrosion resistant coating. For use in hazardous areas with all international certificates. Useable in all industries. FTL51 offers functional safety SIL2\/SIL3. With the second line of defense highest degree of safety and availability of the device can be guaranteed. Reliable measurement values, not affected by:\u003cbr\u003echanging media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.\u003cbr\u003ePoint level switch for all liquids with highly corrosion-resistant coating.\u003cbr\u003e* Process connections: Flanges and hygienic process connection (FDA conform with PFA)\u003cbr\u003e* Temperature: -50 to +150°C (-58 to +302°F)\u003cbr\u003e* Pressure: -1 to +40bar (-14.5 to +580psi)\u003cbr\u003e* Sensor material: ECTFE, PFA (Edlon, Rubyred, conductive), Enamel\u003cbr\u003e* International explosion protection certificates, overfill protection WHG, SIL, hygienic certificates, marine approvals\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e * Use in safety systems requiring functional safety to SIL2\/SIL3 in accordance with IEC 61508\/IEC 61511-1\u003cbr\u003e* Different plastic coating (PFA) and enamel coating for applications with aggressive medias\u003cbr\u003e* International explosion protection certificates and overfill protection certificate (WHG)\u003cbr\u003e* No calibration required, easy to start up\u003cbr\u003e* No mechanically moving parts: no maintenance, no wear, long operating life. Monitoring of fork for damage: guaranteed function\u003cbr\u003e* Second line of defense to protect the environment\u003cbr\u003e* Variety of standardized process connections for all applications\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201247375202\" module-title=\"detailSingleImage\" render=\"true\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv module-id=\"201247375202\" module-title=\"detailSingleImage\" render=\"true\"\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201247375202\" module-title=\"detailSingleImage\" render=\"true\"\u003e\u003c\/div\u003e\n\u003cdiv module-id=\"201247375203\" module-title=\"detailTableHorizontal\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eitem\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003evalue\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eGrade\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eIndustrial\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eWarranty\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e1 Year\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCustomized support\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eOEM\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePlace of Origin\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eGermany\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eBrand Name\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eEndress+Hauser\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eModel Number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eLiquiphant FTL51C\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMaterial\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eECTFE \u003cbr\u003ePFA (Edlon) \u003cbr\u003ePFA (Rubyred) \u003cbr\u003ePFA (conductive) \u003cbr\u003eEnamel\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMode\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePoint Level Switch\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMeasuring Principle\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eVibration Liquids\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCharacteristic \/ Application\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eHigh protection against aggressive media by using antistatic coating \u003cbr\u003eModular housing concept \u003cbr\u003ewide range of process connections \u003cbr\u003eAnalogue and bus interfaces \u003cbr\u003eExtensive certificate range (e.g.Ex,WHG) \u003cbr\u003epipe extension up to 3m (6m option)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSpecialities\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eFoamdetection \u003cbr\u003eDetekt a densitychange \u003cbr\u003esecond line of defense\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSupply \/ Communication\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePROFIBUS PA \u003cbr\u003e19...253V AC, 2-wire \u003cbr\u003e10...55V DC-PNP, 3-wire \u003cbr\u003eDPDT, 19...253V AC, 10...55V DC \u003cbr\u003e8\/16mA, 11...36V DC \u003cbr\u003eNAMUR \u003cbr\u003ePFM, 2-wire \u003cbr\u003eNAMUR with testbutton\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eAmbient Temperature\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e-50 °C...+70 °C \u003cbr\u003e(-58 °C...+158 °F)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProcess Temperature\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e-50 °C...+150 °C \u003cbr\u003e(-58 °F...+302 °F) \u003cbr\u003eup to 230 °C \/ 450°F on request\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProcess Pressure \/ Max. Overpressure Limit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eVacuum...40 bar \u003cbr\u003e(Vacuum...580 psi)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMin. Density Of Medium\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e0.5g\/cm³(0.4g\/cm³ optional)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMain Wetted Parts\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eECTFE \u003cbr\u003ePFA (Edlon) \u003cbr\u003ePFA (Rubyred) \u003cbr\u003ePFA (conductive) \u003cbr\u003eEnamel\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProcess Connection\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eFlange: \u003cbr\u003eDN25...DN100, \u003cbr\u003eASME 1\"...3\", \u003cbr\u003eJIS RF10 K 50\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProcess Connection Hygienic\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eFDA conform with PFA (Edlon)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSensor Length\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eECTFE, PFA 130mm, 148mm...3000mm \u003cbr\u003e(ECTFE, PFA 5.12\", 5.83\"...118\") \u003cbr\u003eEnamel 130mm, 148mm...1200mm \u003cbr\u003e(Enmal 5.12\", 5.83\"...47.24\")\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCommunication\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePROFIBUS PA \u003cbr\u003e19...253V AC \u003cbr\u003e10...55V DC-PNP \u003cbr\u003e19...253V AC bzw 10...55V DC \u003cbr\u003e8\/16mA, 11...36V DC \u003cbr\u003eNAMUR \u003cbr\u003ePFM\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCertificates \/ Approvals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eATEX, FM, CSA C\/US, IEC Ex, TIIS, INMETRO, NEPSI\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSafety Approvals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSIL2\/ SIL3\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eDesign Approvals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eEN 10204-3.1\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eMarine Approval\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eGL\/ ABS\/ DNV\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eOptions\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eHeavy duty stainless steel housing mainly for the oil and gas industry\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eComponents\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eFTL325P\/FTL375P Interface PFM \u003cbr\u003eFTL325N\/FTL375N Interface NAMUR\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201247375205\" module-title=\"detailSellerRecommend\" render=\"true\"\u003e\u003c\/div\u003e\n\u003cdiv module-id=\"201247375213\" module-title=\"detailTextContent\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48885726118105,"sku":null,"price":1360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_Vibronic_Point_Level_Detection_Liquiphant_FTL51C_61aceaac-4b13-4ad4-9cf5-7737bf136ec6.png?v=1783105752","url":"https:\/\/www.aloinfobrasil.com\/es\/products\/endresshauser-vibronic-point-level-detection-liquiphant-ftl51c","provider":"aloinfousa.com","version":"1.0","type":"link"}