{"product_id":"endress-hauser-absolute-and-gauge-pressure-cerabar-pmc71","title":"Endress+Hauser Absolute And Gauge Pressure Cerabar PMC71","description":"\u003ch1\u003eOverview\u003c\/h1\u003e\u003cp\u003eEndress+Hauser Absolute And Gauge Pressure Cerabar PMC71 is a digital pressure transmitter with oil-free ceramic sensor for measurement in gases or liquids.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e* Accuracy\u003cbr\u003eStandard: 0.05%\u003cbr\u003ePlatinum: up to 0.025%\u003cbr\u003e* Process temperature\u003cbr\u003e-40°C...150°C\u003cbr\u003e(-40°F...302°F)\u003cbr\u003e* Pressure measuring range\u003cbr\u003e100mbar...40bar\u003cbr\u003e(1.5psi...600psi)\u003cbr\u003e* Process pressure \/ max. overpressure limit\u003cbr\u003e60bar (900psi)\u003cbr\u003e* Main wetted parts\u003cbr\u003eCeraphire ceramic\u003cbr\u003eAlloy C\u003cbr\u003e316L\u003cbr\u003eMonel\u003cbr\u003ePVDF\u003cbr\u003e* Max. measurement distance\u003cbr\u003e400m (1312ft) H2O\u003cbr\u003e* Material process membrane\u003cbr\u003eCeramic\u003cbr\u003e* Measuring cell\u003cbr\u003e100 mbar...40 bar\u003cbr\u003e(1.5 psi...600 psi)\u003cbr\u003erelative\/ absolute\u003c\/p\u003e\u003ch1\u003eField of application\u003c\/h1\u003e\u003cp\u003eThe Cerabar PMC71 digital pressure transmitter with capacitive, oil-free ceramic measuring cell is typically used in the process and hygienic applications for pressure, level, volume or mass measurement in liquids and gases. It guarantees high degree of system safety thanks to vacuum-proof ceramic membrane with integrated breakage detection. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2\/3 according to IEC 61508.\u003cbr\u003e\u003cbr\u003eTwo chamber aluminum or stainless steel (316L) housing.\u003cbr\u003e* Process connections: Threads, flanges or hygienic connections\u003cbr\u003e* Process temperature: -40 to +150°C (-40 to +302°F)\u003cbr\u003e* Measuring ranges: -1\/0 up to to +40bar (+1.5 to +600psi)\u003cbr\u003e* Accuracy: ±0.05%, \"Platinum\" ±0.025%\u003cbr\u003e* International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals\u003c\/p\u003e\u003ch1\u003eBenefits\u003c\/h1\u003e\u003cp\u003e * Best fit for vacuum applications and applications with corrosive and abrasive media\u003cbr\u003e* Process safety through membrane breakage detection\u003cbr\u003e* Overload-resistant high purity ceramic sensor (99.9% Al2O3)\u003cbr\u003e* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics\u003cbr\u003e* Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus\u003cbr\u003e* Highest safety due to gastight feedthrough with capabilities up to SIL2\/3, certified to IEC 61508\u003cbr\u003e* Available with mounted manifolds: always fit, always tested for leaks\u003c\/p\u003e\u003ch1\u003eSpecification\u003c\/h1\u003e\u003cfigure class=\"table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eitem\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003evalue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCustomized support\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePlace of Origin\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eEndress+Hauser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eModel Number\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCerabar PMC71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Principle\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAbsolute and gauge pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCharacteristic\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDigital transmitter with capacitive sensor and ceramic membrane \u003cbr\u003eModular transmitter \u003cbr\u003eLong term stability \u003cbr\u003eEnhanced safety via self diagnostic functions \u003cbr\u003eSecondary process barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4...20 mA HART \u003cbr\u003e10,5...45V DC (Non Ex): \u003cbr\u003eEx ia: 10,5...30V DC \u003cbr\u003ePROFIBUS PA: \u003cbr\u003e9...32 V DC (Non Ex) \u003cbr\u003eFOUNDATION Fieldbus: \u003cbr\u003e9...32 V DC (Non Ex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eReference Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eStandard: 0.05% \u003cbr\u003ePlatinum: up to 0.025%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLong Term Stability\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e0.05 % of URL\/ year \u003cbr\u003e0.08 % of URL\/ 5 years \u003cbr\u003e0.1 % of URL\/ 10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProcess Temperature\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-20°C...150°C \u003cbr\u003e(-4°F...257°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e-40°C...85°C \u003cbr\u003e(-40°F...185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Cell\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e100 mbar...40 bar \u003cbr\u003e(1.5 psi...600 psi) \u003cbr\u003erelative\/ absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSmallest Calibratable Span\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e5 mbar (0.075 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVacuum Resistance\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e0 mbar abs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Turn Down\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Overpressure Limit\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e60 bar (900 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProcess Connection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eThread: \u003cbr\u003eG1\/2...G2, R1\/2, MNPT1\/2...MNPT2 \u003cbr\u003eFlange: \u003cbr\u003eDN25...DN80, \u003cbr\u003eASME 1\"...4\", \u003cbr\u003eJIS 10K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProcess Connection Hygienic\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTri-Clamp \u003cbr\u003eDIN11851 \u003cbr\u003eVarivent N \u003cbr\u003eSMS \u003cbr\u003eDRD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Process Membrane\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCeramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Gasket\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eViton, EPDM, Chemraz, Kalrez, NBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFill Fluid\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003enone, dry measuring cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Housing\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDie-cast aluminum, \u003cbr\u003eAISI 316L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCommunication\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4...20 mA HART \u003cbr\u003ePROFIBUS PA \u003cbr\u003eFOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCertificates \/ Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eATEX, FM, CSA, CSA C\/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMarine Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eGL\/ ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDrinking Water Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSpecialities\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDiagnostic functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSuccessor\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePMC71B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020379533529,"sku":null,"price":1031.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_19.png?v=1771970795","url":"https:\/\/www.aloinfobrasil.com\/ja\/products\/endress-hauser-absolute-and-gauge-pressure-cerabar-pmc71","provider":"aloinfousa.com","version":"1.0","type":"link"}