{"product_id":"endresshauser-hydrostatic-level-measurement-deltapilot-fmb70","title":"Endress+Hauser Hydrostatic Level Measurement Deltapilot FMB70","description":"\u003cstyle\u003e#detail_decorate_root .magic-0{width:750px}#detail_decorate_root .magic-1{overflow:hidden;width:750px;height:587px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-2{margin-top:0;margin-left:0;width:750px;height:587px}#detail_decorate_root .magic-3{overflow:hidden;width:750px;height:73px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-4{margin-top:0;margin-left:0;width:750px;height:73px}#detail_decorate_root .magic-5{width:446px}#detail_decorate_root .magic-6{overflow:hidden;width:446px;height:594.6666666666666px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-7{margin-top:-1.1893333333333334px;margin-left:-80.87466666666667px;width:594px;height:594px}#detail_decorate_root .magic-8{width:300px;display:flex;flex-direction:column;margin-right:0;margin-left:4px}#detail_decorate_root .magic-9{font-size:20px}#detail_decorate_root .magic-10{vertical-align:top}#detail_decorate_root .magic-11{vertical-align:top;display:inline-block;padding-right:4px;width:50%;box-sizing:border-box;margin-bottom:-4px;padding-left:4px;margin-top:-4px}#detail_decorate_root .magic-12{padding:0;margin:0}#detail_decorate_root .magic-13{padding:0;margin:0;color:#333;font-size:14px;line-height:20px;font-weight:bold;white-space:pre-wrap}#detail_decorate_root .magic-14{vertical-align:top;padding-bottom:4px;box-sizing:border-box;padding-top:4px}#detail_decorate_root .magic-15{padding:0;margin:0;white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-16{white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-17{overflow:hidden;width:750px;height:75px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-18{margin-top:0;margin-left:0;width:750px;height:75px}#detail_decorate_root .magic-19{width:750px;border-collapse:collapse}#detail_decorate_root .magic-20{min-height:28px;padding:5px 10px;width:259px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-21{min-height:28px;padding:5px 10px;width:442px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-22{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-23{overflow:hidden;width:750px;height:1078px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-24{margin-top:0;margin-left:0;width:750px;height:1078px}#detail_decorate_root .magic-25{overflow:hidden;width:750px;height:814px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-26{margin-top:0;margin-left:0;width:750px;height:814px}#detail_decorate_root .magic-27{overflow:hidden;width:750px;height:758px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-28{margin-top:0;margin-left:0;width:750px;height:758px}#detail_decorate_root .magic-29{overflow:hidden;width:750px;height:583px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-30{margin-top:0;margin-left:0;width:750px;height:583px}#detail_decorate_root .magic-31{overflow:hidden;width:750px;height:893px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-32{margin-top:0;margin-left:0;width:750px;height:893px}#detail_decorate_root .magic-33{overflow:hidden;width:750px;height:675px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-34{margin-top:0;margin-left:0;width:750px;height:675px}#detail_decorate_root .magic-35{overflow:hidden;width:750px;height:76px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-36{margin-top:0;margin-left:0;width:750px;height:76px}#detail_decorate_root .magic-37{vertical-align:top;display:block;padding-right:4px;box-sizing:border-box;padding-left:4px}\u003c\/style\u003e\n\u003cdiv id=\"detail_decorate_root\" data-magic-global=\"%7B%22bizId%22%3A2217607044645%2C%22pageId%22%3A200110912721%2C%22siteId%22%3A10100897032%7D\"\u003e\n\u003cdiv render=\"true\" module-title=\"detailSingleImage\" module-id=\"201248644401\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailSingleImage\" module-id=\"201248644402\"\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailHorizontalImageText\" module-id=\"201248644403\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eHighest performance pressure sensor with the Contite cell for hydrostatic level measurement.\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e* Accuracy\u003cbr\u003eStandard 0.1%\u003cbr\u003eOptional 0.075%\u003cbr\u003e* Process temperature\u003cbr\u003e-10°C...+100°C\u003cbr\u003e(+14°F...+212°F)\u003cbr\u003e* Pressure measuring range\u003cbr\u003e100 mbar...10 bar\u003cbr\u003e(1.5 psi...150 psi)\u003cbr\u003e* Process pressure \/ max. overpressure limit\u003cbr\u003e40 bar (600 psi)\u003cbr\u003e* Main wetted parts\u003cbr\u003eAlloy C\u003cbr\u003e316L\u003cbr\u003e* Max. measurement distance\u003cbr\u003e100 m (328 ft) H2O\u003cbr\u003e* Material process membrane\u003cbr\u003e316L, AlloyC,\u003cbr\u003eGold-Rhodium\u003cbr\u003e* Measuring cell\u003cbr\u003e100 mbar...10 bar\u003cbr\u003e(1.5 psi...150 psi)\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailDoubleTitleParagraph\" module-id=\"201248644404\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eField of application\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM\/M-DAT data module makes management of process and device parameters\u003cbr\u003eeasy. Designed according to IEC 61508 for use in SIL3 safety systems.\u003cbr\u003eFor level and\/or pressure measurement.\u003cbr\u003e* Process connections: Threads, flanges and hygienic connections\u003cbr\u003e* Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)\u003cbr\u003e* Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)\u003cbr\u003e* Accuracy: ±0.075%\u003cbr\u003e* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e * Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation\u003cbr\u003e* Best batch-to-batch repeatability and long-term stability\u003cbr\u003e* Modular concept for easy replacement of display or electronics\u003cbr\u003e* HistoROM\/M-DAT data backup for instrument settings and measured values\u003cbr\u003e* Function-monitored from the measuring cell to the electronics\u003cbr\u003e* Seamless and independent system integration (HART\/PA\/FF)\u003cbr\u003e* International usage thanks to a wide range of approvals\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailSingleImage\" module-id=\"201248644891\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailSingleImage\" module-id=\"201248644891\"\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailSingleImage\" module-id=\"201248644891\"\u003e\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailTableHorizontal\" module-id=\"201248644406\"\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eitem\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003evalue\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eGrade\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eIndustrial\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eWarranty\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e1 Year\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eCustomized support\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eOEM\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003ePlace of Origin\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eGermany\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eBrand Name\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eEndress+Hauser\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eModel Number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eDeltapilot FMB70\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eMeasuring Principle\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eHydrostatic pressure\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eCharacteristic\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003ePressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: \u003cbr\u003eHermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences \u003cbr\u003eCompact version\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eSupply Voltage\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e4...20 mA HART \u003cbr\u003e10,5...45 VDC (Non Ex): \u003cbr\u003eEx ia: 10,5...30 VDC \u003cbr\u003ePROFIBUS PA: \u003cbr\u003e9...32 VDC (Non Ex) \u003cbr\u003eFOUNDATION Fieldbus: \u003cbr\u003e9...32 VDC (Non Ex)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eReference Accuracy\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eStandard 0.1% \u003cbr\u003eOptional 0.075%\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eLong Term Stability\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e0.05 % of URL\/year\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eProcess Temperature\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e-10°C...100°C \u003cbr\u003e(14°F...212°F)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eAmbient Temperature\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e-40°C...85°C \u003cbr\u003e(-40°F...185°F)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eMeasuring Cell\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e100 mbar...10 bar \u003cbr\u003e(1.5 psi...150 psi)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eSmallest Calibratable Span\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e25 mbar (3.63 psi)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eVacuum Resistance\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e0 mbar abs.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eMax. Overpressure Limit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e40 bar (600 psi)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eProcess Connection\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eThread: \u003cbr\u003eG1 1\/2, MNPT1 1\/2 \u003cbr\u003eFlange: \u003cbr\u003eDN40...DN100, \u003cbr\u003eASME 2\"...4\", \u003cbr\u003eJIS 10K\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eMaterial Process Membrane\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e316L, AlloyC, \u003cbr\u003eGold-Rhodium\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eMaterial Gasket\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eNone, measuring cell welded\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eFill Fluid\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eInert oil, \u003cbr\u003eSynthetic oil\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eMaterial Housing\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e316L, Die-cast aluminum\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eCommunication\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e4 ... 20 mA HART \u003cbr\u003ePROFIBUS PA \u003cbr\u003eFOUNDATION Fieldbus\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eCertificates \/ Approvals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eATEX, FM, CSA, CSA C\/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eSafety Approvals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eSIL\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eDesign Approvals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eEN10204-3.1 \u003cbr\u003eNACE MR0175 \u003cbr\u003eMR0103\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eHygienic Approvals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e3A, EHEDG \u003cbr\u003eCoC ASME-BPE\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eMarine Approvals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eGL, DNV\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eDrinking Water Approvals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eNSF\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eSpecialities\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eGold-rhodium coated membrane\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailSellerRecommend\" module-id=\"201248644408\"\u003e\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailTextContent\" module-id=\"201248644416\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48885721825497,"sku":null,"price":2640.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_Hydrostatic_Level_Measurement_Deltapilot_FMB70_d0c2f32a-6bb6-4ce9-9182-ff0dac55c03b.png?v=1783105705","url":"https:\/\/www.aloinfobrasil.com\/products\/endresshauser-hydrostatic-level-measurement-deltapilot-fmb70","provider":"aloinfousa.com","version":"1.0","type":"link"}