{"product_id":"juniper-acx6160-t-dc-router-s03gd","title":"Juniper ACX6160-T-DC Router","description":"\u003cdiv class=\"short-hide\" data-mce-fragment=\"1\"\u003e[shortdesc]\n\u003cul data-mce-fragment=\"1\"\u003e\n\n\u003cli data-mce-fragment=\"1\"\u003eACX6400, 100G\/200G OpenROADM compliant transponder supporting pluggable CFP2 DCO DWDM optics, with 2 x DC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp class=\"p1\"\u003e[properties]\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"222\"\u003e\n\u003ccol width=\"364\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Properties\"}'\u003eProperties\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Juniper ACX6160-T-DC\"}'\u003eJuniper ACX6160-T-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Description\"}'\u003eDescription\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ACX6160 Optical Transport, supports 8x100GbE SFP28\/QSFP+ client ports, 4x100\/200G CFP2-DCO pluggable DWDM optics, redundant fans and redundant DC power supplies, front-to-back airflow\"}'\u003eACX6160 Optical Transport, supports 8x100GbE SFP28\/QSFP+ client ports, 4x100\/200G CFP2-DCO pluggable DWDM optics, redundant fans and redundant DC power supplies, front-to-back airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Product Family\"}'\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ACX6000 Series\"}'\u003eACX6000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Product Type\"}'\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Router\"}'\u003eRouter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Built-In Interface Options\"}' colspan=\"2\" rowspan=\"1\"\u003eBuilt-In Interface Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"100GbE (QSFP28)\"}'\u003e100GbE (QSFP28)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"8\"}'\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"100\/200 Gbps (CFP2-DCO)\"}'\u003e100\/200 Gbps (CFP2-DCO)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"4*\"}'\u003e4*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"*ACX6160 initial release will be limited to 100G CFP2 line rate\"}' colspan=\"2\" rowspan=\"1\"\u003e*ACX6160 initial release will be limited to 100G CFP2 line rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Dimension (WxHxD)\"}'\u003eDimension (WxHxD)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"17.36 x 1.72 x 24.40 in (44.09 x 4.37 x 61.98 cm) \"}'\u003e17.36 x 1.72 x 24.40 in (44.09 x 4.37 x 61.98 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Weight (lb\/kg) fully configured\"}'\u003eWeight (lb\/kg) fully configured\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"24 lb (10.9 kg)\"}'\u003e24 lb (10.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Power\"}'\u003ePower\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"-40 to -72 VDC power\"}'\u003e-40 to -72 VDC power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Maximum power draw\"}'\u003eMaximum power draw\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"500 W (with optical small form-factor pluggable transceivers)\"}'\u003e500 W (with optical small form-factor pluggable transceivers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Rack unit\"}'\u003eRack unit\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"1 U\"}'\u003e1 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e[\/properties][specifications]\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"383\"\u003e\n\u003ccol width=\"393\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Specifications\"}'\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ACX6160-T-DC\"}'\u003eACX6160-T-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"System Throughput\"}'\u003eSystem Throughput\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"1.6\/3.2 Tbps\"}'\u003e1.6\/3.2 Tbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Operating temperature\"}'\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"32° to 104° F (0° to 40° C)\"}'\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Humidity\"}'\u003eHumidity\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"5%-90% RH noncondensing\"}'\u003e5%-90% RH noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Platform Features\"}'\u003ePlatform Features\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Link Layer Discovery Protocol (LLDP)\\nNETCONF\\nSNMP v2\/v3\\nSLAX\/Python on-box scripting tools\\nZTD\\nYANG \"}'\u003eLink Layer Discovery Protocol (LLDP)\u003cbr\u003eNETCONF\u003cbr\u003eSNMP v2\/v3\u003cbr\u003eSLAX\/Python on-box scripting tools\u003cbr\u003eZTD\u003cbr\u003eYANG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Safety Approvals\"}'\u003eSafety Approvals\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"CAN\/CSA-C22.2 No. 60950-1\\nUL 60950-1\\nEN 60950-1\\nIEC 60950-1CB Scheme\\nEN 60825-1 \"}'\u003eCAN\/CSA-C22.2 No. 60950-1\u003cbr\u003eUL 60950-1\u003cbr\u003eEN 60950-1\u003cbr\u003eIEC 60950-1CB Scheme\u003cbr\u003eEN 60825-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"EMC\"}'\u003eEMC\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"AS\/NZS CISPR22\\nClass A\\nEN55022 Class A\\nVCCI Class A\\nFCC Part 15 Class A\\nIECS-003 Issue 4\\nBSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions\\nKN 22, Class\\nEN-61000-4-6 Low Frequency Common Immunity\\nEN-61000-4-11 Voltage Dips and Sags\\nCISPR 24\/EN55024 Information Technology Equipment Immunity\\nCharacteristics\"}'\u003eAS\/NZS CISPR22\u003cbr\u003eClass A\u003cbr\u003eEN55022 Class A\u003cbr\u003eVCCI Class A\u003cbr\u003eFCC Part 15 Class A\u003cbr\u003eIECS-003 Issue 4\u003cbr\u003eBSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions\u003cbr\u003eKN 22, Class\u003cbr\u003eEN-61000-4-6 Low Frequency Common Immunity\u003cbr\u003eEN-61000-4-11 Voltage Dips and Sags\u003cbr\u003eCISPR 24\/EN55024 Information Technology Equipment Immunity\u003cbr\u003eCharacteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ETSI (European Telecommunications Standardization Institute)\"}'\u003eETSI (European Telecommunications Standardization Institute)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"EN 300 386 V1.6.1 Telecommunication Network Equipment, Electromagnetic Compatibility Requirements\\nETSI EN 300 019-2-1 (2000)Storage, Class T1.2\\nETSI EN 300 019-2-2 (1999)Transportation, Class T2.3\\nETSI EN 300 019-2-3 (2003)Stationary Use at Weather\\nProtected Locations, Class T3.2\\nETSI 300753 (1997)Acoustic Noise Emitted by Telecommunications Equipment\"}'\u003eEN 300 386 V1.6.1 Telecommunication Network Equipment, Electromagnetic Compatibility Requirements\u003cbr\u003eETSI EN 300 019-2-1 (2000)Storage, Class T1.2\u003cbr\u003eETSI EN 300 019-2-2 (1999)Transportation, Class T2.3\u003cbr\u003eETSI EN 300 019-2-3 (2003)Stationary Use at Weather\u003cbr\u003eProtected Locations, Class T3.2\u003cbr\u003eETSI 300753 (1997)Acoustic Noise Emitted by Telecommunications Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Other EMC Requirements\"}'\u003eOther EMC Requirements\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Deutsche Telekom 1TR9 (2008) EMC Specification\\nBritish Telecom EMC Immunity Requirements (2007)\"}'\u003eDeutsche Telekom 1TR9 (2008) EMC Specification\u003cbr\u003eBritish Telecom EMC Immunity Requirements (2007)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"NEBS\"}'\u003eNEBS\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"SR-3580 NEBS Criteria Levels (Level 3 Compliance)\\nGR-63-CORE: NEBS, Physical Protection\\nTelecommunications Equipment (Issue 6 compliant)\"}'\u003eSR-3580 NEBS Criteria Levels (Level 3 Compliance)\u003cbr\u003eGR-63-CORE: NEBS, Physical Protection\u003cbr\u003eTelecommunications Equipment (Issue 6 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Telecomm Compliance\"}'\u003eTelecomm Compliance\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Device management: NETCONF, CLI, SNMP v1\/v2\/v3\\nEnd-to-end provisioning of E-Line, emulated LAN (ELAN), Layer 3 VPN (L3VPN), OAM, class of service (CoS)\\nDevice and service-level fault management\\nDevice and service-level performance management\"}'\u003eDevice management: NETCONF, CLI, SNMP v1\/v2\/v3\u003cbr\u003eEnd-to-end provisioning of E-Line, emulated LAN (ELAN), Layer 3 VPN (L3VPN), OAM, class of service (CoS)\u003cbr\u003eDevice and service-level fault management\u003cbr\u003eDevice and service-level performance management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e[\/specifications][accesories] [\/accesories]\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eJuniper ACX6000 line of Universal Metro Routers directly addresses evolving metro network architectures that extend operational intelligence from the service provider edge to the access network. The ACX6000 line bridges the complexity between packet optical transport and the IP\/MPLS networking layer by collapsing both domains into a seamless, multilayer solution. From there, it delivers a single-pane-of-glass view into network operations.\u003c\/span\u003e\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013230178521,"sku":"ACX6160-T-DC-NEW","price":38585.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ACX6160_4ff4c7e6-38dd-4e0c-8901-d23efcdbafdd.jpg?v=1771852361","url":"https:\/\/www.aloinfobrasil.com\/sr\/products\/juniper-acx6160-t-dc-router-s03gd","provider":"aloinfousa.com","version":"1.0","type":"link"}