{"product_id":"fluke-87v-true-rms-industrial-multimeter-i0kri","title":"Fluke 87V True RMS Industrial Multimeter","description":"\u003cp\u003e[shortdesc] True-RMS accuracy, 1000 V AC\/DC, 10 A current range, VFD low-pass filter, 200 kHz frequency, CAT III 1000 V\/CAT IV 600 V [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"172\" style=\"width: 172px;\"\u003e\n\u003ccol width=\"340\" style=\"width: 340px;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFluke 87V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Digital Multimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage (AC\/DC\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current (AC\/DC\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003eUp to 50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003eUp to 9,999 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003eUp to 200 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−200 °C to 1090 °C (probe dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductance\u003c\/td\u003e\n\u003ctd\u003eUp to 60.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test Range\u003c\/td\u003e\n\u003ctd\u003e3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6000 counts (19,999 in high-resolution mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eTwo-level bright backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e9V battery (installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e~400 hours (without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−20 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0–90% (0–35 °C, 0–70% (35–55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H × W × D\u003c\/td\u003e\n\u003ctd\u003e201 × 98 × 52 mm (with holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e355 g (624 g with holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Rating\u003c\/td\u003e\n\u003ctd\u003e1 m drop (IEC 61010-1:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eMIL-PRF-28800 Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"172\" style=\"width: 172px;\"\u003e\n\u003ccol width=\"340\" style=\"width: 340px;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003eMax 1000 V; Accuracy ±(0.05% + 1; Resolution 10 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003eMax 1000 V; Accuracy ±(0.7% + 2 True RMS; AC Bandwidth 20 kHz (LPF enabled; 3 dB @ 1 kHz; Resolution 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003eMax 10 A (20 A for 30 sec; Accuracy ±(0.2% + 2; Resolution 0.01 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003eMax 10 A (20 A for 30 sec; Accuracy ±(1.0% + 2 True RMS; Resolution 0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eRange up to 50 MΩ; Accuracy ±(0.2% + 1; Resolution 0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eMax 9,999 µF; Accuracy ±(1% + 2; Resolution 0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eMax 200 kHz; Accuracy ±(0.005% + 1; Resolution 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003eMax 99.9%; Accuracy ±(0.2% per kHz + 0.1%; Resolution 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd\u003e−200 °C to 1090 °C (meter; with 80BK probe: −40 °C to 260 °C; Accuracy ±2.2 °C or 2% whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductance\u003c\/td\u003e\n\u003ctd\u003eUp to 60.00 nS; Accuracy ±(1.0% + 10; Resolution 0.01 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003eRange 3 V; Resolution 1 mV; Accuracy ±(2% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Conditions\u003c\/td\u003e\n\u003ctd\u003eOperating: −20 °C to 55 °C; Storage: −40 °C to 60 °C; Humidity: 0–90% (0–35 °C, 0–70% (35–55 °C; Altitude: 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Approvals\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1 CAT III 1000 V \/ CAT IV 600 V; CE, CSA, RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Performance\u003c\/td\u003e\n\u003ctd\u003eDigital 6000 counts (4\/sec, 19,999 high-res mode; Analog bar graph 32 segments (40\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"172\" style=\"width: 172px;\"\u003e\n\u003ccol width=\"340\" style=\"width: 340px;\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded (Standard Package\u003c\/td\u003e\n\u003ctd\u003eTL75 Test Leads; AC175 Alligator Clips; Holster; 9V Battery (installed; 80BK Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded (87V CAL Version\u003c\/td\u003e\n\u003ctd\u003eAll standard items + Traceable calibration certificate with data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003eFluke TPAK ToolPak Magnetic Meter Hanger; Fluke TLK-225 SureGrip Master Accessory Set; Fluke CXT80 Extreme Case; Fluke Pack30 Professional Tool Backpack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003ePrecision Diagnostics for Demanding Industrial Environments\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 87V Industrial Multimeter delivers the accuracy and resolution required to troubleshoot motor drives, power distribution panels, automation systems and electromechanical equipment even in noisy, high-energy environments. Its advanced low-pass filter ensures precise measurements on variable frequency drives (VFDs, while Peak Capture functionality identifies fast intermittents down to 250 µs for reliable problem isolation. Built to Fluke’s highest safety standards, the 87V withstands spikes above 8000 V and operates confidently in challenging field conditions.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS performance:\u003c\/strong\u003e Achieves accurate readings on complex, noisy or non-linear loads common in VFD and automation systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-pass VFD filter:\u003c\/strong\u003e Enables stable, precise voltage measurements on motor drives by filtering high-frequency noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-speed peak capture:\u003c\/strong\u003e Detects intermittents as short as 250 µs, essential for monitoring unstable signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable industrial build:\u003c\/strong\u003e Rated CAT III 1000 V and CAT IV 600 V with specially designed shielding that blocks high-energy electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced visibility \u0026amp; usability:\u003c\/strong\u003e Features a bright two-level backlight, analog bar graph and Touch Hold for easier field work.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTesting and diagnosing\u003cstrong\u003e \u003c\/strong\u003evariable-frequency motor drives\u003c\/li\u003e\n\u003cli\u003eIndustrial automation maintenance and plant operations\u003c\/li\u003e\n\u003cli\u003ePower distribution and electrical panel troubleshooting\u003c\/li\u003e\n\u003cli\u003eField service in high-energy or high-altitude environments (up to 2000 m operating altitude\u003c\/li\u003e\n\u003cli\u003ePrecision testing for electromechanical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Measurement:\u003c\/strong\u003e 1000 V AC\/DC (True RMS ±0.7% + 2 AC; ±0.05% + 1 DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Measurement:\u003c\/strong\u003e 10 A (20 A for 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e Up to 50 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Up to 9,999 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e Up to 200 kHz (0.01 Hz resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuty Cycle:\u003c\/strong\u003e 0–99.9%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e −200 °C to 1090 °C (meter only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Ratings:\u003c\/strong\u003e CAT III 1000 V, CAT IV 600 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 6000–19,999 counts, analog bar graph\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e Approximately 400 hours (without backlight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUpgrade Your Test Precision Today\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrder now\u003c\/strong\u003e and equip your toolkit with industry-leading accuracy.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":48012858720473,"sku":"FLUKE-87-V-NEW","price":508.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/2725d18d-633b-40b2-b09b-b108002e4d59_original__size_ec09fda0-f1a3-4069-8262-4338eba43d63.webp?v=1771846871","url":"https:\/\/www.aloinfobrasil.com\/uk\/products\/fluke-87v-true-rms-industrial-multimeter-i0kri","provider":"aloinfousa.com","version":"1.0","type":"link"}