item
|
value
|
|
Warranty
|
1 Year
|
|
Customized support
|
OEM
|
|
Place of Origin
|
Switzerland
|
|
Brand Name
|
Endress+Hauser
|
|
Model Number
|
Promass E200
|
|
Type
|
Coriolis meters, Coriolis flowmeter
|
|
Measuring Principle
|
Coriolis
|
|
Product Headline
|
Genuine loop-powered flowmeter for minimized cost of ownership. Accurate measurement of liquids and gases for a wide range of standard applications.
|
|
Sensor Features
|
Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi).
|
|
Transmitter Features
|
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
|
|
Nominal Diameter Range
|
DN 8 to 50 (⅜ to 2")
|
|
Wetted Materials
|
Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L)
|
|
Measured Variables
|
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
|
|
Max. Measurement Error
|
Mass flow (liquid): ±0.25 % (standard) Volume flow (liquid): ±0.25 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³
|
|
Measuring Range
|
0 to 70 000 kg/h (0 to 2570 lb/min)
|
|
Max. Process Pressure
|
PN 100, Class 600, 63K
|
|
Medium Temperature Range
|
–40 to +150 °C (–40 to +302°F)
|
|
Ambient Temperature Range
|
–40 to +60 °C (–40 to +140 °F)
|
|
Sensor Housing Material
|
1.4301 (304), corrosion resistant
|
|
Transmitter Housing Material
|
AlSi10Mg, coated
|
|
Degree Of Protection
|
IP66/67, type 4X enclosure
|
|
Display/Operation
|
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
|
|
Outputs
|
4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
|
|
Inputs
|
None
|
|
Digital Communication
|
HART, PROFIBUS PA, FOUNDATION Fieldbus
|
|
Power Supply
|
DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch) DC 18 to 30 V (20 mA HART, 4‐20 mA) DC 9 to 32 V (PROFIBUS PA)
|
|
Hazardous Area Approvals
|
ATEX, IECEx, cCSAus, JPN, UK Ex
|
|
Product Safety
|
CE, C-Tick
|
|
Functional Safety
|
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
|
|
Metrological Approvals And Certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
|
|
Pressure Approvals And Certificates
|
PED, CRN
|
|
Material Certificates
|
3.1 material
|
|
Hygienic Approvals And Certificates
|
3-A, EHEDG, cGMP
|