AXG1A High Grade Transmitter
|
|
|
|
Accuracy (Reading Value)
|
[Sensor Combination] - AXW: ± 0.35 %
|
[Sensor Combination] - AXW: ± 0.35 %
|
± 0.35 %
|
|
Size
|
[Sensor Combination] - AXW: 25 to 1800 mm
|
[Sensor Combination] - AXW: 25 to 1000 mm
|
25 to 1000 mm
|
|
Use
|
[Tansmitter] - General Purpose [Sensor Combination] - General Purpose - Explosion Protection - Submersible
|
[Tansmitter] - General Purpose - Explosion Protection [Sensor Combination] - General Purpose - Explosion Protection - Submersible
|
General Purpose Explosion Protection
|
|
Explosion Protection Use
|
IECEx, ATEX, Korea, Brazil (INMETRO), EAC * Transmitter is usable only in the safety area.
|
IECEx, ATEX, Korea, Brazil (INMETRO), EAC
|
|
|
Liner Material
|
PTFE, Polyurethane, Natural Soft Rubber, Natural Hard Rubber
|
|
|
|
Communication Protocols
|
HART 7, BRAIN
|
HART 7, BRAIN, Modbus FOUNDATION Fieldbus PROFIBUS PA EtherNet / IP
|
|
|
Signal Cable Length
|
200 m
|
100 m
|
|
|
Main Function
|
- Easy Setup Wizard - Trend Graph Display Function - Data Logging Function (with microSD card) - Parameter Backup / Restore / Duplication Function (with microSD card) - Zero Adjustment - Display Test Function - Input/Output Test Function
|
|
|
|
Diagnostic Function
|
[Application Diagnostics] - Electrode Adhesion Detection - Sensor Empty Check - Wiring Connection Diagnosis - Flow Noise Diagnosis - Low Conductivity Diagnosis - Electrode Insulation - Deterioration Diagnosis
|
[Application Diagnostics] - Electrode Adhesion Detection - Sensor Empty Check - Wiring Connection Diagnosis
|
|
|
|
[Verification Function] - Built-in Verification - Standard Verification (with FSA130 ADMAG TI Verification Tool) - Enhanced Verification (with FSA130 ADMAG TI Verification Tool)
|
|
|
|
Current Signal
|
Input: 1 ch (Active) Output: 2 ch (Active)
|
Output: 1 ch (Active)
|
|
|
Pulse/Status Signal
|
Output: 2 ch (Active [With / Without Internal Resister] / Passive)
|
Output: 2 ch (Active [Without Internal Resister] / Passive)
|
|
|
Status Signal
|
Input: 2 ch (Dry Contact) Output: 2 ch (Passive)
|
Input: 1 ch (Dry Contact)
|
|
|
Alarm Signal
|
Output: 1 ch (Passive)
|
-
|
|
|
Multiple Languages
|
English, French, German, Italian, Spanish, Portuguese, Russian and Japanese.
|
|
|
|
Safety Integrity Level
|
|
SIL2
|
|
|
Others
|
[AXG1A/AXW4A Transmitter, AXW Integral Type] - LCD with improved environmental resistance
[AXG1A Transmitter] - Equipped with temperature input terminal for Density correction and Calolie calculation
|
|
|